updatedAt: 2026-08-06T13:21:54.000Z
agentTools:
  projectIndex: https://docs.axonius.com/llms.txt
---

# Philips PerformanceBridge Focal Point

Philips PerformanceBridge Focal Point is a clinical surveillance management server that aggregates patient monitors, PIIC hosts, access points, and access point controllers across healthcare facilities via SNMP.

### Use Cases the Adapter Solves

* **Healthcare Device Visibility:** Gain complete visibility into all Philips clinical devices across your healthcare facilities, including patient monitors, PIIC hosts, wireless access points, and access point controllers.
* **Clinical Infrastructure Management:** Track and manage the deployment, location, and status of critical patient monitoring equipment and supporting network infrastructure across hospitals and care facilities.

### Asset Types Fetched

* Devices

## Data Retrieved through the Adapter

**Devices**

For example:

* Host Name, IP Address, MAC Address

## Before You Begin

### Required Ports

* UDP port 161 (SNMP)

### Authentication Methods

**SNMP Community String (SNMPv1/v2c) or SNMPv3 Credentials**

The adapter connects to the Philips PerformanceBridge Focal Point server using SNMP protocol. You can use either:

* **SNMPv1/v2c**: Requires a read community string
* **SNMPv3**: Requires username, authentication password, privacy password, and protocol settings

### APIs

Axonius uses the Philips PerformanceBridge Focal Point SNMP agent. The following SNMP MIB tables are queried:

* `msHostTable (1.3.6.1.4.1.38222.1.1.1.2.6)` - Retrieves PIIC host information
* `msMonitorTable (1.3.6.1.4.1.38222.1.1.1.2.3)` - Retrieves patient monitor information
* `msApTable (1.3.6.1.4.1.38222.1.1.1.2.1)` - Retrieves Smart Hopping Access Point information
* `msApcTable (1.3.6.1.4.1.38222.1.1.1.2.2)` - Retrieves Access Point Controller information

**Note:** The adapter uses the PHILIPS-MANAGEMENT-SYSTEM-MIB (enterprise OID 1.3.6.1.4.1.38222).

### Required Permissions

The SNMP agent on the Philips PerformanceBridge Focal Point server must be configured to allow read access to the device tables listed above.

#### SNMPv1/v2c

* **Read-only community string** - Allows SNMP GET and WALK operations on the Philips MIB tables

#### SNMPv3

* **Read-only user credentials** - User account with read access to the Philips MIB tables
* **Authentication and Privacy protocols** - Configured according to your organization's security requirements

**Note:** The exact permission names should be confirmed with your Philips administrator or Philips support, as the API documentation is not publicly available.

### Supported From Version

Supported from Axonius version 9.0.4

## Connecting the Adapter in Axonius

Navigate to the Adapters page, search for Philips PerformanceBridge Focal Point, and click on the adapter tile.

Click **Add Connection**.

To connect the adapter in Axonius, provide the following parameters:

### Required Parameters

1. **Host Name** - The hostname or IP address of the Philips PerformanceBridge Focal Point server. Example: `focal-point.hospital.local` or `10.0.1.100`
2. **Version** - The SNMP version to use. Options: `1`, `2c`, or `3`. Default: `2c`&#x20;

![]()

<br />

### Optional Parameters

1. **User Name** - The SNMPv3 user name (only required when using SNMP version 3).
2. **SNMP Read Community** - The SNMP community string for read access (required for SNMPv1 and SNMPv2c).
3. **SNMPv3 Authentication Password (authKey)** - The authentication password for SNMPv3 (only required when using SNMP version 3 with authentication).
4. **SNMPv3 Private Password (privKey)** - The privacy password for SNMPv3 (only required when using SNMP version 3 with privacy).
5. **SNMPv3 Authentication Type (authProtocol)** - The authentication protocol for SNMPv3. Options: `NO_AUTH`, `MD5`, `SHA`, `SHA224`, `SHA256`, `SHA384`, `SHA512`. Default: `NO_AUTH`
6. **SNMPv3 Privacy Type (privProtocol)** - The privacy protocol for SNMPv3. Options: `NO_PRIV`, `DES`, `3DES`, `AES`, `AES192`, `AES256`. Default: `NO_PRIV`
7. **Port** - The SNMP port number. Default: `161`
8. **HTTPS Proxy** - Connect the adapter to a proxy instead of directly connecting it to the domain.
9. **HTTPS Proxy User Name** - The user name to use when connecting to the value supplied in **Host Name** via the value supplied in **HTTPS Proxy**.
10. **HTTPS Proxy Password** - The password to use when connecting to the server using the **HTTPS Proxy**.

<br />

To learn more about common adapter connection parameters and buttons, see [Adding a New Adapter Connection](https://docs.axonius.com/axonius-help-docs/docs/adding-a-new-adapter-connection).

<br />